-
0,27 $ netto
Eltek Minipack 1U is a small and efficient power supply system equipped with 2 rectifiers with a power of 800 W. The total power of the entire system is 1600 W. Minipack includes the Compack controller and DC distribution protection.
The height of the device is 1U, the design facilitates access to the AC, DC and alarm terminals even in cases where other devices are installed directly below and above. The depth of the casing is 250 mm, thanks to which the power system supply fits perfectly into ETSI cabinets.
The most important features:
- reliability;
- small size;
- high power density;
- external or integrated distribution;
- digital control;
- cooling;
- unique "plug & play" connection;
- global approval: device meets CE and UL requirements.
Specification:
Minipack 1U | |
AC Input | |
---|---|
Voltage |
85 - 300 V AC (nominal 185 - 276 V AC). Single or two-phase power supply, linear power limitation below 185 V AC. |
Termial AC | 2.5 mm2 (12 AWG) Terminal Clamps |
Maximum current |
4.9 A rms for one rectifier maximum at nominal input voltage and full load. Leakage current: 1.7 mA at 250 V AC / 50 Hz |
Input protection | Internal protection of the rectifier |
Control | |
Controller | Compack |
Local control | WWW interface - communication using a standard web browser or using the PowerSuite software |
Remote control | PowerSuite or WEB software. Interface, SNMP protocol and email |
Alarm outputs | 3 alarm relays (NO, NC, C) |
Visual indicators |
Green LED - the system is operational, no damage yellow LED - alarm (s) not urgent red LED - urgent alarm (s) |
Digital inputs |
3 multifunctional inputs Can be used for temperature measurement, digital or analog monitoring. |
Current measurement |
Battery current rectifier current |
Alarms |
Receiving fuse blows the battery fuse blows Tripping of the LVD contactor low output voltage (2 alarm levels) high output voltage (2 alarm levels) wrong battery capacity temperature alarm battery symmetry alarm |
DC Output | |
Voltage | 48 V DC |
Power | 400 - 1600W (maximum 33A at 48 V DC) |
DC distribution options | |
Receiver protection |
Collective DC output (not protected) 4x (2-16A), glass protections 5x20 mm |
Battery protection | 2x30 A |
Programmable LVBD | LVBD: 30A |
Connectors | |
Battery connection / connection for external distribution | Clamp connectors 10 mm2 |
Przy??cza wy??czników odbiorów | Clamp connectors 4,0 mm2 (AWG 11) |
Przy??cza alarmowe | Clamp connectors 1,5 mm2 (AWG 12) |
System | Extendable frame allowing easy access to the gym clamps |
Other parameters | |
Insulation |
3.0 kV AC input-output 1.5 kV AC input-ground 0.5 kV DC output to ground |
Working temperature | From -40 to 75 °C |
Storage temperature | From -40 to 80 °C |
Dimensions |
19 "width (446 mm + mounting brackets) height 1U, depth 250 mm Recommended housing depth: minimum 300 mm |
Weight (without rectifiers) | About 2,66 kg |
Standards | |
Safety |
IEC 60950-1 UL 60950-1 |
EMC |
ETSI EN 300 386 V.1.3.2 (telecommunications networks) EN 61000-6-1 (resistance, light industry) EN 61000-6-2 (immunity, industry) EN 61000-6-3 (emission, light industry) EN 61000-6-4 (emission, industry) |
Enviroment |
ETSI EN 300 019 ETSI EN 300 132-2 |